Line 182: Line 182:     
* <s>Fix 2 pin hole leaks (one at each end of tank)</s>
 
* <s>Fix 2 pin hole leaks (one at each end of tank)</s>
* Better drains (one drain hole per square in the base of the tank all plumbed together with a single drain valve)
+
* <s>Fit bladder input line (so it doesn't collect crap in the tank)</s>
* Fit bladder input line on the side of the tank (so it doesn't collect crap in the tank)
   
* Wash out old compressor tank
 
* Wash out old compressor tank
* Trim the top of the side where the A axis hardware grazes the top of the tank.
+
* <s>Trim the top of the side where the A axis hardware grazes the top of the tank.</s>
 
* Paint the outside of the tank
 
* Paint the outside of the tank
* Treat the water with the green goo (last once everything else is complete in this section)
+
* <s>Treat the water with the green goo</s>
    
Plumbing/wiring todo:
 
Plumbing/wiring todo:
Line 217: Line 216:  
Roundness/cut quality todo:
 
Roundness/cut quality todo:
    +
* <s>Y Axis pulsing - new connection spigot for drive year to fix eccentric rotation of gear</s>
 
* Remove and clean X axis gears, reinstall and use loctite on set screws (the keep backing off)
 
* Remove and clean X axis gears, reinstall and use loctite on set screws (the keep backing off)
 
* Make sure all bearings are right against the rails so there is no slop
 
* Make sure all bearings are right against the rails so there is no slop
* Investigate backlash and configure mach3 is required
+
* <s>Investigate backlash and configure mach3 is required</s> - 0.0001 on X, Y and A
 
* Get quote for installing ground rod next to the table and execute it
 
* Get quote for installing ground rod next to the table and execute it
* Look into THC issues (cut rippling) if still present after ground rod
+
* Look into THC issues (cut rippling) if still present after ground rod - possible Z axis flex in the mount to the Y carriage.
 
* Why is the THC seeing ~80V for a good clean cut from the hypertherm?  Is the internal voltage divider broken (is this why the machine was retrofitted with a dangerous high voltage tap?)? Or is this related to a bad ground at the table?
 
* Why is the THC seeing ~80V for a good clean cut from the hypertherm?  Is the internal voltage divider broken (is this why the machine was retrofitted with a dangerous high voltage tap?)? Or is this related to a bad ground at the table?
 
* Motion pauses: (Seen on large 3'x2' complex cuts)
 
* Motion pauses: (Seen on large 3'x2' complex cuts)
** Do we need to add a CV on G-Code in the preamble of the post processor
+
** Why are there zero move G1's at the end of curves generated with G2's
 +
** <s>Do we need to add a CV on G-Code in the preamble of the post processor</s> - Does not appear to need this
 
** Smooth stepper under-run errors - I have only seen this when jogging not cutting, mostly related to rapiding the Z, maybe reduce the micro stepping on the driver for the new threaded drive step count is huge per inch which could be hurting us
 
** Smooth stepper under-run errors - I have only seen this when jogging not cutting, mostly related to rapiding the Z, maybe reduce the micro stepping on the driver for the new threaded drive step count is huge per inch which could be hurting us
** Axis and Core frequency tuning for the smooth stepper?
+
** <s>Axis and Core frequency tuning for the smooth stepper?</s> - Dropped to 64k on X,Y,A
** Look ahead tuning
+
** <s>Look ahead tuning</s> - increased to 150
 
** Is CV plasma mode hurting us?
 
** Is CV plasma mode hurting us?
** System problems, AV jamming things up?
+
** <s>System problems, AV jamming things up?</s> - low cpu load not an issue
     