Power Panels

If you find out what a circuit breaker does, make sure it's numbered in the box and that information about what it powers ends up here. If possible, label the outlet box as well. What form this document takes remains to be seen; hopefully we will get a solid amount of information into it so further work on our electrical system won't totally be explorative.

First Floor

PP1-1

Back of the shop by the loading dock. Can't miss it.

Some sketchy shit in this one.

Single phase and 2 pole circuits wired to 3 phase breakers.

Several high amp 3 phase breakers that are unmapped.


Breaker # Used What Is It
8&10&12 unused 3 phase, 20 amp, 3 black. Wiring trough, boiler room. Dust collection circuit thru existing disconnect.
19&16&18 used 2-120v circuits on a 3 phase breaker. Blue wires. Boiler & zone pumps, this is bad and wrong.
22 unused this is a stray 208v single red wire on a 3 phase breaker that runs to wiring troughin the boiler room. Should be disconnected and abandoned.(used to be paired with wires pp1-2 # 35&37)

PP1-2

Back of the shop by the loading dock. Can't miss it.

Breaker # Used What Is It
6 Yes, works 20amp, 2 outlets hot metal side of furnace room, short drop near center of shop. Light in the boiler room.
8 Yes, works 20 amp, outlet at hot metal side of furnace room, possibly second outlet behind lockers.
7,9,11 yes. works. Power to chiller/heat pump on the roof for AC... and also the air handler under it inside. The
25 yes , works Lights at catwalk and kitchen, outlet at kitchen fridge.
26 yes, works Currently connected to the entire east wall. This includes dust collector and Clausing electronics. Please do not connect chop saw table to east wall while others are working.
35&37 used Compressor 40 amp 1 phase 240v thru a 35 amp disconnect in boiler room.

Small fuse box

Back of the shop, left of PP1-1, above the light switches.
Left fuse, exit signs.

PB1-1

An unremarkable box full of wires.

PB1-2

Power box connected to PP1-1 by conduit. Bridges the A/C heat pump/air handler circuit, among other things. The 3-phase for A/c heat pump and air handler is bridged such that the entire 3 phase comes from PP1-1 up to the roof via PB1-2, and a branch switched on the roof by relay comes back down in the same conduit that goes the the roof. This circuit is passed via conduit to the air handler, and switched manually on the bottom of the air handler.

PP1-3

Metal shop, by the lathes.

Breaker # Used What Is It
1, a&b yes, works 20 amp.
3, a&b ?
5&7, a&b yes, works 50 amp, 240v, cold metal.
5b & 7a yes works 20 amp 240v, dedicated Clausing lathe.

PP1-4

In the tool cage.

Breaker # Used What Is It
12 yes 20 amp, 120v, south wall of the shop.
14 yes 20 amp, 120v, south wall of the shop.
18&20 yes, works 50 amp, 240v, hot metal at welding area.
23 yes 20 amp 120v, south wall of the shop.
24&26 yes, works 15 amp, 240v, shopbot.
37 yes, works 20 amp, 120v, hot metal at welding area.

PP1-5

Cold Metal shop,

Breaker # Used What Is It
1 in use landlord circuit, don't touch
2 in use landlord circuit, don't touch
3 in use landlord circuit, don't touch
4 in use landlord circuit, don't touch
5 in use landlord circuit, don't touch
6 in use landlord circuit, don't touch
7 in use landlord circuit, don't touch
8 in use landlord circuit, don't touch
9
10
11
12
13
14
15
16 in use kitchen, above counter outlets.
17
18 in use 3 outlets, metal shop side of kitchen wall.
19
20

PP1-6

In the safe in the lounge. The top big breaker is the service disconnect for the whole box. This box covers everything in the lounge, the front entryway, and the upstairs bathroom.

Breaker # Used Amperage What Is It
1 in use 30 Tandem with #3 - Lounge Everything. Upstairs bathroom for reasons unknown.
2 in use 20 Safe
3 in use 30 Tandem with #1 - Lounge Everything. Upstairs bathroom for reasons unknown.
4 in use 20 AC wall
5 in use 20 Bathrooms off lounge
6 in use 20 Bar wall
7 in use 20 Lounge lights
8 unused none
9 unused none
10 unused none
11 unused none
12 unused none
13 unused none
14 unused none
15 unused none
16 unused none
17 unused none
18 unused none
19 unused none
20 unused none

TODO: take down notes from tape in the box, mark them in table above

PP1-7

Blue fuse box in the furnace room. Powers just the air compressor.

PP1-8

3515, by the back door

This is mostly the lights and outlets in the main room, and the loading dock

Breaker # Used What Is It
1 Yes Lights
2 Yes Wall Outlets
3 Yes Lights
4 Yes Wall Outlets
5 Yes Wall Outlets
6 Yes Wall Outlets
7 Yes Wall Outlets
8 Yes Wall Outlets
9 Yes Wall Outlets
10 Yes Wall Outlets
11 Yes Exhaust Fan
12 Yes Wall Outlets
13 Yes Loading Dock (lights, outlet, garage door)
14 Yes Lights
15 No
16 Yes Lights
17 No
18 Yes Lights
19 No
20 Yes Outlet-- ceiling drop

PP1-9

3515, by the back door, This is a 3-phase panel

This includes the lights and outlets in the meeting room.

Breaker # Used What Is It
1 & 3 & 5 ? (Labeled "Compressor")
2 & 4 & 6 ?
7 & 9 & 11 ?
8 & 10 Yes Twist-lock outlet in meeting room
12 Yes Wall outlets in meeting room
13 & 15 & 17 Yes Outlets by back door
14 & 16 ?
18 ?
19 & 21 & 23 ?
20 & 22 ? (Labeled "Charger")
24 Yes Wall outlets in meeting room
25 Yes Lights in meeting room
26 Yes Wall outlets in meeting room
27 No
28 No
29 No
30 No
31 No
32 No
33 No
34 No
35 & 37 Yes Feeds PP1-8?
36 No
38 No
39 & 41 ?
40 No
42 No

Second Floor

PP2-1

In the AC/comms closet upstairs.

Breaker # Used Amperage What Is It
1 in use 100 Main breaker for box - Tandem with #3
3 in use 100 Main Breaker for box - Tandem with #1
5 20 Tandem with #7
6 20
7 20 Tandem with #5
8 in use 20 Back stairwell lights, catwalk lights, night light in the shop..
9 20
10 in use 20 Mid lights
11 20
12 in use 20 Electronics area lights
13 in use 20 CNC area
14 in use 20 Arts lights
15 in use 20 Electronics area north wall (light switch)
16 20
17 20
18 in use 20 Shop heating radiator fans and thermostats.
19 15
20 in use 15 Outlet in closet
21 30 Tandem with #23
22 unused none
23 30 Tandem with #21
24 unused none


PP2-2

On the catwalk.
This is a 3 phase panel,"High Leg Delta" configuration, http://en.wikipedia.org/wiki/High-leg_delta The center bus bar is 208v to neutral.

Breaker # Used Amperage What Is It
1 in use 20 above kitchen ceiling, servers on catwalk
2 in use 20 2 lower outlets, in kitchen either side of door. Outlet at SEM location
3 Not used none 208 volts to neutral, not recommended for use except in 3 phase circuit.
4 Not used none 208 volts to neutral, not recommended for use except in 3 phase circuit.
5 in use split 20 2 circuits a&b, Beer church.
6 in use 20 Tandem with #8 - 240v, Oven, 8 gauge, 4 wires, capable of 50 amps
7 in use 20
8 in use 20 Tandem with #6 - 240v, Oven, 8 gauge, 4 wires, capable of 50 amps
9 Not used none 208 volts to neutral, not recommended for use except in 3 phase circuit.
10 Not used none 208 volts to neutral, not recommended for use except in 3 phase circuit.
11 in use 20 Laser
12 in use 20 Tandem with #14 - 240v, kitchen, above counter. For induction cook top
13 in use 30 Tandem with #15 & #17 - Bridgeport
14 in use 20 Tandem with #12 - 240v, kitchen, above counter. For induction cook top
15 in use 30 Tandem with #13 & #17 - Bridgeport
16 Not used none 208 volts to neutral, not recommended for use except in 3 phase circuit.
17 in use 30 Tandem with #13 & #15 - Bridgeport
18 in use 20 Outlet at SEM location

Electrical Punch List

Desired Circuits

Hot Metals

Wood Shop

drops: http://www.mcmaster.com/#4804k12/=pmf353 ??

Other goodies

100 amp 5 wire 3 phase disconnect with lugs sufficient for #1 feeder cable. This could be located anywhere that is convenient.

Light Switches

Upstairs

There are five lighting circuits upstairs, four of which are on three-way switches.

  • There is a switch next to the front stairway for stairwell and upstairs landing (the other switch is at the bottom of the stairs). Leave this light on.
  • There are three switches on the Arts side of the stairwell labelled 'Arts' 'Electronics' and 'Mid'. There is an identical set of switches by the door to the back stairway.
    • Arts is two rows of lights on the arts side of the upstairs
    • Electronics is two rows of lights on the electronics side
    • Mid is one row of lights in electronics and one row in the arts area
  • Many of the fixtures in electronics have individual pull-switches (wall switch must be on)
  • The switch for the lights in front of the shelves on the north wall of the electronics lab is behind the shelves. Follow the conduit that comes down from the ceiling.

Shop

The shop lights are near the back door-- look to the left of the loading dock, to the left of the electrical panels with the clock sitting on top. There's a row of lightswitches with a red panel around them.

Unfortunately, there's no way to turn them on from the other end of the shop. There is one light that's supposed to stay on, but sometimes it gets turned off. There's a switch in the kitchen with a sign that says something like "don't turn this off", but it doesn't say why. I think there may be another switch somewhere else.


The "Don't turn this switch off" switch is a 4-way switch; the other two are 1: next to the back door, and 2: behind the CNC Bridgeport (which would be a useful place if we used that sliding fire door into the Abbey "lounge" area)


There are a few more lights in the shop that don't need to be left on overnight.1) above the woodworking sanding equipment- pull the plug. 2) to the left of the manual Bridgeport there is a switch controlling the lights overhead. 3) on the cold metals island there is a power strip for the lights above. 4) to the right of the sink in hot metals is a wall switch.


Lounge

  • Four switches by the front entrance that control the lights in the main part of the room
  • Two switches by the safe to the left, one for the safe lights and one for the short hall by the doorway to the shop
  • One switch to the right of the safe, that controls the outlet on the ceiling in the center of the room.