(Add intake and exhaust info)
Line 63: Line 63:
  
 
The front room has a thermostat near the safe. This system is independently controlled by the same boiler system in the boiler room.
 
The front room has a thermostat near the safe. This system is independently controlled by the same boiler system in the boiler room.
 +
 +
== Outside air exchange ==
 +
 +
=== Shop ===
 +
 +
==== Fresh air intake ====
 +
 +
There is a large powered air intake mounted above the boiler room and the hot metal area. The landlord indicated (7/1/14) that this system needs to be operational to satisfy city inspection. The electrical circuit (3 phase) for this unit was disconnected and the 240v portion was relocated to the compressor. In addition, the wiring from the disconnect to the magnetic motor starter was removed. This probably occurred shortly after we occupied the building. The disconnect immediately below the motor was relocated to the mill 2/14.
 +
The heating feature of this intake was disconnected by the landlord prior to our arrival.
 +
 +
Failure to make this operational may result in fines.
 +
 +
==== Exhaust ====
 +
 +
Roof vents
 +
 +
2 powered vents. Switched at the back of the shop by the electrical panels. The south unit is not operational and needs diagnosis and repair. The north unit is operational and seems to be thermostatically controlled (not verified). Unknown size or capacity.
 +
 +
Laser. 4", current cfm unknown.
 +
 +
Cold metal 10"?
 +
 +
Central shop 10"?
 +
 +
 +
Wall vents
 +
 +
Catwalk 4"
 +
 +
North wall. 4" DO NOT USE!  It is a code violation to vent in this manner.
 +
 +
 +
=== Boiler Room ===
 +
 +
Powered exhaust, north wall.  Switched in proximity. Near the compressor.
 +
 +
Automatic fresh air intake. East wall.
 +
  
 
== Maintenance ==
 
== Maintenance ==

Revision as of 14:26, 2 July 2014

Cooling

Lounge

There is a wall mount A/C unit that is sort of old and may contain extraneous growth in the lounge. Should be investigated and cleaned to mitigate liability.

Shop

There is a heat pump / air handler cooling system mounted on the ceiling and roof.

These are some very vague and poorly collated notes about that:

heat pump stat - but we aren't using the heat pump for heating, so we don't even need the fancy board since it's for defrost. we use it when we're cooling only. Right now, the wire from the roof is wired to make it so when power is on (7,9,11) PP1-1 - it runs all the time. There is no relay control of it that's active. the red wire in the control wire will throw a relay on and off to control the heat pump.

but, we don't need to use the heat mode of the unit and it's not wired upstairs for it at the moment, so we should set up the filtrete like so -

take off silver jumper, use RC and Y. (normal cooling, not heat pump cooling - the transformer is ganged right to the relay up top). thin red wire on the transformer goes to RC thick red wire from the roof goes to Y blue and white should be stuck together like they are.


we also need to put the air handler/fan unit on the coil that hangs down (big tan thing) run always if the heat pump is on, since it will ice up otherwise. However, it's also useful when things aren't in cooling mode for running some air from outside to the shop, so we want a switch that can manually trigger the relay that will be controlling the air handler.


According to Everrett, the AC in the shop froze up sometime between mid june and late april 2014. Eric Stein noted that the switch box on the bottom of the shop AC was open in mid june. That's probably not good. Presumably, nobody read the HVAC wiki page before trying to do things with HVAC. For shame!


Upstairs

There is an HVAC unit in the comms/hvac closet upstairs near the side stairs.

Quick Facts:

  • International Comfort Products Corporation
  • Model No: FBF100F14A4
  • Mfg No: NTG3100GFA4
  • Serial No: L0114187076
  • manual

Heating Zones

The upstairs and the downstairs are the 2 separate heating zones.

Upstairs

The thermostat is by the closet across from the top of the front stairs, in the craft area. The heat and cooling are in the closet.

Downstairs

The room in the back left corner of the main room (looking toward the back of the building) contains our boiler and our hot water tank.

The thermostat is located in the metal shop area. The manual is at [1] but it has not yet been configured using the wifi module.

The front room has a thermostat near the safe. This system is independently controlled by the same boiler system in the boiler room.

Outside air exchange

Shop

Fresh air intake

There is a large powered air intake mounted above the boiler room and the hot metal area. The landlord indicated (7/1/14) that this system needs to be operational to satisfy city inspection. The electrical circuit (3 phase) for this unit was disconnected and the 240v portion was relocated to the compressor. In addition, the wiring from the disconnect to the magnetic motor starter was removed. This probably occurred shortly after we occupied the building. The disconnect immediately below the motor was relocated to the mill 2/14. The heating feature of this intake was disconnected by the landlord prior to our arrival.

Failure to make this operational may result in fines.

Exhaust

Roof vents

2 powered vents. Switched at the back of the shop by the electrical panels. The south unit is not operational and needs diagnosis and repair. The north unit is operational and seems to be thermostatically controlled (not verified). Unknown size or capacity.

Laser. 4", current cfm unknown.

Cold metal 10"?

Central shop 10"?


Wall vents

Catwalk 4"

North wall. 4" DO NOT USE! It is a code violation to vent in this manner.


Boiler Room

Powered exhaust, north wall. Switched in proximity. Near the compressor.

Automatic fresh air intake. East wall.


Maintenance

Some of our HVAC systems require regular maintenance.

Pumps

In the boiler room the two red pumps that force hot water for radiant heat in the front room and the shop area. These pumps have three ports for oil lubrication. The two ports on either side of the pump get 3 drops of oil each, the covered port over the bearing needs one strong squirt. This needs to be done annually. This was last preformed 4/9/14.

Filter

The furnace upstairs has a filter that will need to be changed every winter.