Difference between revisions of "Mitsui Surface Grinder"

From Pumping Station One
Jump to navigation Jump to search
(Update repair and setup)
m
Line 9: Line 9:
 
|certification=yes  
 
|certification=yes  
 
|hackable=no
 
|hackable=no
|value=~$3000}}
+
|value=~$3000
 +
|hostarea=Cold Metals
 +
}}
  
 
== Repair and Setup==
 
== Repair and Setup==

Revision as of 15:37, 21 February 2017


Mitsui Surface Grinder
File:Mitsui250mh.jpg
Owner/Loaner Dean Anderson
Serial Number {{{serial}}}
Make/Model Mitsui 250MH
Arrival Date Late 2016
Usability so close
Contact Dean Anderson
Where Cold Metals
Authorization Needed yes
Hackable no
Estimated Value ~$3000
Host Area Cold Metals


Mitsui Surface Grinder Dean Anderson Area: Cold Metals https://wiki.pumpingstationone.org/wiki/Mitsui_Surface_Grinder



Repair and Setup

All repair needs to be coordinated with the area host.

Motor bearings were replaced, to great success. Ball ways and table are installed. Test grinds are showing good repeatability. A grit and light parts catcher is installed on the left hand side.

  1. Remove saddle, clean ways and check turcite for damage.
  2. Z ways need to be cleaned.
  3. Replace Z way pleated covers.
  4. Fill lubrication tank with correct oil. Check that all oil lines are working.
  5. Remove the grinder from the pallet and align parallel to the long wall. Set up the materials storage and maybe plywood on the right side.
  6. Install a full wheel guard.
  7. Develop an authorization plan.

Diagnosis

After initial repair, diagnosis of further issues will come via a test grind.

  1. The table may need to be ground in.
  2. A mag chuck will need to be ground in and swept with an indicator.
  3. Five block test can be used as a rough diagnosis.

Table Removal

The table needs to be removed periodically to clean the grinding grit from the ways.

The table is heavy. We need a system for lifting the table off of the saddle. THe engine hoist doesn't work well. Perhaps a ceiling supported crane would work.

  1. Remove the nut at the end of the cable on the right side under the table. Fasten a weight to the end of the cable to prevent the cable from unwinding on the capstan.

Moving the grinder

The ball ways need to be removed anytime the grinder is moved. This is necessary to prevent the races from Brinelling. To remove the ball ways, disconnect the X axis cable at each end of the table then prop up the ends of the table.