== History ==
 
== History ==
 +
 +
This vote was somewhat obsoleted by the [[Vote to Refresh PS:One Server Hardware]] which intends to lower power consumption in the rack and provide clean power via line conditioner.
    
== Background ==
 
== Background ==
   −
Our UPS is failing.
+
We currently have a single UPS unit functioning - this unit is able to supply enough power for our network storage (which serves as the hard drives for all of our virtual machines, primarily).
 +
 
 +
This means the two servers that currently run all space-hosted services (The wiki, the member's site, domain authentication and probably some other stuff) are powered directly from a wall circuit. This is not ideal - minor power dips will temporarily bring down all services and power issues could also damage the servers. That's bad news.
 +
 
 +
In a perfect world, we would have enough new UPS hardware to cover our existing needs as well as enabling us to expand a bit (We have two more servers that are currently powered down) and keep our network running strong. Purchasing two of either models linked below would cover our existing needs and offer enough headroom to be useful in the future.
 +
 
 +
This vote is also an opportunity to revisit power on the catwalk - currently there are two dedicated circuits (which need to be upgraded to 30 amps if we go with the CyberPower units) that are very difficult to access since the kitchen was built. It would be nice to relocate these to be somewhat closer to the rack.
    
=== Rack Utilization ===
 
=== Rack Utilization ===
Line 59: Line 67:  
** There are 2 power runs in the rack, fewer may be ok
 
** There are 2 power runs in the rack, fewer may be ok
 
* Interface Port Type: USB
 
* Interface Port Type: USB
* Backup Time: ??
+
* Backup Time: 5 minutes
 
* Cost: ??
 
* Cost: ??
   Line 68: Line 76:  
! VA/Watt
 
! VA/Watt
 
! Price
 
! Price
 +
! Full Load Run Time
 
|-
 
|-
 
| APC Smart-UPS RM SMT3000RM2U
 
| APC Smart-UPS RM SMT3000RM2U
 
| 3000VA/2700W
 
| 3000VA/2700W
 
| [http://www.amazon.com/APC-Smart-UPS-SMT3000RM2U-3000VA-System/dp/B004F0BD2K/ $1,151.99]
 
| [http://www.amazon.com/APC-Smart-UPS-SMT3000RM2U-3000VA-System/dp/B004F0BD2K/ $1,151.99]
 +
| ?
 
|-
 
|-
| CyberPower PR3000LCDRT2U
+
| APC ATX 4000 Power Supply SUA5000RMT5U
| 3000VA/2250W
+
| 5000VA/4000W
| [http://www.amazon.com/gp/product/B001RJGDXQ $760.99]
+
| [http://www.amazon.com/APC-4000-Power-Supply-SUA5000RMT5U/dp/B000XTZXVY $2,250.00 + $437.45 shipping ]
 +
|
 +
|-
 +
| APC AP7920 Switched 1 U PDU
 +
| power distribution
 +
| [https://www.apc.com/products/resource/include/techspec_index.cfm?base_sku=AP7920 $549.00 ]
 +
| N/A
 
|}
 
|}
    
== Language ==
 
== Language ==
 +
 +
Authorize the expenditure of as much as $2000 to replace PS:1's network power conditioning and facilitate installation thereof.