Anonymous

Changes

From Pumping Station One
Line 8: Line 8:  
|serial = 0003929870
 
|serial = 0003929870
 
|arrived = Oct. 16, 2021
 
|arrived = Oct. 16, 2021
 +
|manual = https://wiki.pumpingstationone.org/images/SchultzMsw_60_max.pdf
 
|where = Boiler Room
 
|where = Boiler Room
 
|doesitwork = yes
 
|doesitwork = yes
Line 16: Line 17:  
The compressor is a two-stage machine rated for 40 cfm at 175 psi. It has a 120 gallon tank. It is fitted with a 10 hp 3-phase motor that is fed from PP1-7 (the safety switch in the Boiler Room), which is fed from a 3-phase 60 A breaker in PP1-1. Specified weight is 836 lbs. for the whole machine.
 
The compressor is a two-stage machine rated for 40 cfm at 175 psi. It has a 120 gallon tank. It is fitted with a 10 hp 3-phase motor that is fed from PP1-7 (the safety switch in the Boiler Room), which is fed from a 3-phase 60 A breaker in PP1-1. Specified weight is 836 lbs. for the whole machine.
   −
Air moves from the compressor through a shutoff valve to a filter and the to an air Dryer  Atlas Copco model FD25  The manual is available[https://wiki.pumpingstationone.org/File:Airdryer.pdf right here.]
+
 
 +
 
 +
Air moves from the compressor through a shutoff valve to a filter and the to an air Dryer  Atlas Copco model FD25  The manual is available[https://wiki.pumpingstationone.org/File:Airdryer.pdf right here.]
    
From the dryer, air routes through a high efficiency filter and another shutoff valve.
 
From the dryer, air routes through a high efficiency filter and another shutoff valve.
Line 25: Line 28:     
There is also a dryer bypass circuit for servicing the dryer while the shop continues to used be fed air.  To effect the bypass,open the valve between the compressor (in vertical piping)and the left side of the house circuit mixing piping and close the valve between the dryer and the right side of the house circuit mixing piping.
 
There is also a dryer bypass circuit for servicing the dryer while the shop continues to used be fed air.  To effect the bypass,open the valve between the compressor (in vertical piping)and the left side of the house circuit mixing piping and close the valve between the dryer and the right side of the house circuit mixing piping.
 +
 +
Moisture collected from the tank, lines and dryer are collected in an ejector pump located between the compressor and dryer.  Output goes overhead and down into the floor drain.
    
== Operation ==
 
== Operation ==
Line 32: Line 37:     
== Maintenance ==
 
== Maintenance ==
To be more filled in later.   
+
Manual is here in [https://wiki.pumpingstationone.org/images/SchultzMsw_60_max.pdf manual. ]pdf.  Check oil frequently belts monthly and change oil every 200 hours.   
    
Responsibility for this mostly resides in the General Operations Team. Reminders are available via the PS1 maintenance calendar accessible by maintenance teams.
 
Responsibility for this mostly resides in the General Operations Team. Reminders are available via the PS1 maintenance calendar accessible by maintenance teams.
Line 54: Line 59:  
-Check the pressure switch operation.
 
-Check the pressure switch operation.
 
-Check for oil contamination and change it if necessary.
 
-Check for oil contamination and change it if necessary.
 +
-check and clean filters
    +
=== Bimonthly ===
   −
=== Quarterly===
+
- change oil every 200 working hours or every other month.(Whichever occurs first).
 
  −
-Change the air filter element every 300 working hours or quarterly.(Whichever occurs first).
   
-Fasten bolts and nuts as required.
 
-Fasten bolts and nuts as required.
 
-Change oil more frequently if compressor is located in a very dirty environment.
 
-Change oil more frequently if compressor is located in a very dirty environment.
1,582

edits