The compressor is a two-stage machine rated for 40 cfm at 175 psi. It has a 120 gallon tank. It is fitted with a 10 hp 3-phase motor that is fed from PP1-7 (the safety switch in the Boiler Room), which is fed from a 3-phase 60 A breaker in PP1-1. Specified weight is 836 lbs. for the whole machine.
 
The compressor is a two-stage machine rated for 40 cfm at 175 psi. It has a 120 gallon tank. It is fitted with a 10 hp 3-phase motor that is fed from PP1-7 (the safety switch in the Boiler Room), which is fed from a 3-phase 60 A breaker in PP1-1. Specified weight is 836 lbs. for the whole machine.
   −
  −
== (THIS PIPING IS CURRENTLY BEING BUILT AS OF MID NOVEMBER 2021.  IT SHOULD BE COMPLETED SOON.  IN THE MEANTIME IT IS IN A BASIC BYPASS MODE) ==
        Line 39: Line 37:     
== Maintenance ==
 
== Maintenance ==
(To be more filled in later).   
+
Manual is here in [https://wiki.pumpingstationone.org/images/SchultzMsw_60_max.pdf manual. ]pdf.  Check oil frequently belts monthly and change oil every 200 hours.   
    
Responsibility for this mostly resides in the General Operations Team. Reminders are available via the PS1 maintenance calendar accessible by maintenance teams.
 
Responsibility for this mostly resides in the General Operations Team. Reminders are available via the PS1 maintenance calendar accessible by maintenance teams.
Line 61: Line 59:  
-Check the pressure switch operation.
 
-Check the pressure switch operation.
 
-Check for oil contamination and change it if necessary.
 
-Check for oil contamination and change it if necessary.
 +
-check and clean filters
    +
=== Bimonthly ===
   −
=== Quarterly===
+
- change oil every 200 working hours or every other month.(Whichever occurs first).
 
  −
-Change the air filter element every 300 working hours or quarterly.(Whichever occurs first).
   
-Fasten bolts and nuts as required.
 
-Fasten bolts and nuts as required.
 
-Change oil more frequently if compressor is located in a very dirty environment.
 