− | Our shop needs *real* dust collection. Here lies the start of plans to rectify that. | + | Our shop needs *real* dust collection. Here lies the start of plans to rectify that. |
− | ==Dust Collector== | + | == Dust Collector == |
| http://www.clearvuecyclones.com/cv-max/13-cv-max-three-phase-with-filters.html | | http://www.clearvuecyclones.com/cv-max/13-cv-max-three-phase-with-filters.html |
| | | |
Line 7: |
Line 7: |
| 5 HP motor (Leeson 132242.00 frame 184TC, 86.5% efficiency) | | 5 HP motor (Leeson 132242.00 frame 184TC, 86.5% efficiency) |
| | | |
− | This dust collector will have sufficient flow with two open gates. Occasional use with three gates open is acceptable. The 'nano' filter option ($100) is recommended. | + | This dust collector will have sufficient flow with two open gates. Occasional use with three gates open is acceptable. The 'nano' filter option ($100) is recommended. |
| Collector cost with nano filter is $2070. | | Collector cost with nano filter is $2070. |
| | | |
Line 14: |
Line 14: |
| Clearvue technical support does not recommend mixing wood and metal dust in the same collection system. | | Clearvue technical support does not recommend mixing wood and metal dust in the same collection system. |
| | | |
− | ==Ducting== | + | == Ducting == |
| 6" sewer & drain pipe for drops | | 6" sewer & drain pipe for drops |
| | | |
Line 21: |
Line 21: |
| 8" sewer & drain pipe for main lines | | 8" sewer & drain pipe for main lines |
| | | |
− | ==Automating this stuff== | + | == Automating this stuff == |
| No one will use it if it doesn't turn on automatically. It *must* be automatic. I've read that using less than 3" ducts with a large 15-16" blower is a problem. | | No one will use it if it doesn't turn on automatically. It *must* be automatic. I've read that using less than 3" ducts with a large 15-16" blower is a problem. |
| | | |
Line 28: |
Line 28: |
| * [[File:Blast gate.doc]] | | * [[File:Blast gate.doc]] |
| | | |
− | This is a 2.5" duct, 'cause I originally planned to use the shop vac. The hole can just be enlarged to 3" w/o other changes. For 4" or 6" gates, the plates should be enlarged, and linkages will probably need lengthening. I made a lot of paper models to get the geometry right. Someone with experience modelling moving parts with CAD could probably do the scaling more quickly. | + | This is a 2.5" duct, 'cause I originally planned to use the shop vac. The hole can just be enlarged to 3" w/o other changes. For 4" or 6" gates, the plates should be enlarged, and linkages will probably need lengthening. I made a lot of paper models to get the geometry right. Someone with experience modelling moving parts with CAD could probably do the scaling more quickly. |
| [[File:blast_gate_front.svg]] | | [[File:blast_gate_front.svg]] |
| | | |
− | ==Machines that need collection== | + | == Machines that need collection == |
| * Table saw (needs retrofit 6" pipe inside and out, maybe 5" and an overhead 3" collector) | | * Table saw (needs retrofit 6" pipe inside and out, maybe 5" and an overhead 3" collector) |
| * Jointer | | * Jointer |
Line 44: |
Line 44: |
| * Drill presses | | * Drill presses |
| | | |
− | While all of these machines need dust/debris collection of some sort. Some of them may be better served by water buckets instead of a central dust vacuum. For instance grinders should have their exhausts feed into a bucket with water in it. | + | While all of these machines need dust/debris collection of some sort. Some of them may be better served by water buckets instead of a central dust vacuum. For instance grinders should have their exhausts feed into a bucket with water in it. |
| | | |
− | ==Electrical Needs== | + | == Electrical Needs == |
| | | |
− | The dust collector should be on it's own circuit, switched on by a relay. Switches should be conveniently located near machines, or interlocked to certain machines. | + | The dust collector should be on it's own circuit, switched on by a relay. Switches should be conveniently located near machines, or interlocked to certain machines. |
| | | |
− | ==Costs== | + | == Costs == |
| | | |
| Clearvue CVMAX 3 phase with nano filters $2070 | | Clearvue CVMAX 3 phase with nano filters $2070 |
Line 64: |
Line 64: |
| y pieces of 8"x10' pvc pipe | | y pieces of 8"x10' pvc pipe |
| | | |
− | n 8x8x6 PVC wye $83 each | + | n 8x8x6 PVC wye $83 each |
| | | |
| mounting hardware $200 | | mounting hardware $200 |