Line 11: |
Line 11: |
| |contact = CNC Area Host | | |contact = CNC Area Host |
| |value = $6000 | | |value = $6000 |
− | |image = IMG_4045.JPG | + | |image = Cncplasma.jpg |
| }} | | }} |
| | | |
| == Status == | | == Status == |
| | | |
− | Working. Stay tuned for an announcement about authorizations. | + | Working. |
| | | |
| == Authorization == | | == Authorization == |
Line 240: |
Line 240: |
| | | |
| * Extend air line to under table to create a manifold for table mounted air consumers | | * Extend air line to under table to create a manifold for table mounted air consumers |
− | * Run large conduit for 220 outlet for the plasma cutter | + | * <s>Run large conduit for 220 outlet for the plasma cutter</s> |
| * Run small conduit for data/estop between the table and the PC | | * Run small conduit for data/estop between the table and the PC |
| * Run black pipe for connecting the table to the bladder (old compressor tank) | | * Run black pipe for connecting the table to the bladder (old compressor tank) |
| * Water line from north side of the shop, with input into the old compressor tank | | * Water line from north side of the shop, with input into the old compressor tank |
− | * Air lines to the compressor tank (one vent on from the compressor) | + | * <s>Air lines to the compressor tank (one vent on from the compressor)</s> |
− | * Run ethernet line to PC so its not on wifi any more | + | * <s>Run ethernet line to PC so its not on wifi any more</s> - ''WiFi for network access is fine'' |
| * Z axis limit switches | | * Z axis limit switches |
| | | |
Line 327: |
Line 327: |
| | | |
| === Fine Cut === | | === Fine Cut === |
− |
| |
− |
| |
− | '''THERE IS CURRENTLY NO POST PROCESSOR FOR RUNNING WITH THESE CONSUMABLES INSTALLED'''
| |
− |
| |
| | | |
| '''NOTE''': These parts are for a t30 unshielded torch, they are compatiable with the T45m when it is run at a setting lower than 30A and cutting materials thinner than 3/16". Ohmic sensing will not work with these parts installed. | | '''NOTE''': These parts are for a t30 unshielded torch, they are compatiable with the T45m when it is run at a setting lower than 30A and cutting materials thinner than 3/16". Ohmic sensing will not work with these parts installed. |
Line 1,134: |
Line 1,130: |
| ** Wantai DQ542MA | | ** Wantai DQ542MA |
| ** Manual: [[File:DQ542MA_English_Manual.pdf]] | | ** Manual: [[File:DQ542MA_English_Manual.pdf]] |
− | * SmoothStepper Ethernet | + | |
| + | * Ethernet SmoothStepper |
| + | **https://warp9td.com/index.php/products |
| + | **https://warp9td.com/index.php/documentation/doc-ess |
| + | **https://warp9td.com/index.php/gettingstarted/setting-up-the-smoothstepper-and-mach#THC |
| + | |
| * C25 Break out board | | * C25 Break out board |
| ** https://cnc4pc.com/motion-control/breakout-boards/c25-smooth-stepper-terminal-board.html | | ** https://cnc4pc.com/motion-control/breakout-boards/c25-smooth-stepper-terminal-board.html |
| ** Manual: [[File:C25R3_1_USER_MANUAL.pdf]] | | ** Manual: [[File:C25R3_1_USER_MANUAL.pdf]] |
| + | |
| *Torch height control | | *Torch height control |
| **Proma Compact THC | | **Proma Compact THC |
− | **http://proma-elektronika.com/download/PDF/thc150_en.pdf | + | **http://proma-elektronika.com/download/PDF/thcsd_en.pdf |
| + | **http://proma-elektronika.com/index.php/en/products/thc-torch-height-control/compact-thc-sd |
| | | |
| ==maintenance == | | ==maintenance == |
Line 1,191: |
Line 1,194: |
| |Ron Olson | | |Ron Olson |
| |10/21/18 | | |10/21/18 |
| + | |- |
| + | |Oliver Sanchez |
| + | |Ron Olson |
| + | |01/29/19 |
| + | |- |
| + | |Greg Bell |
| + | |Ron Olson |
| + | |03/23/19 |
| |- | | |- |
| |} | | |} |