| 8/8/15
 
| 8/8/15
| Extensive interior cleaning, soaked and cleaned optics and carriage, soaked and cleaned autofocus plunger, soaked and cleaned vector table in industrial purple, cleaned optical encoder strip, dusted under cover and re-shimmed the aluminum air assist rod so it doesn't rub on the case or circuit board above the cutting head and leave aluminum powder on the encoder strip and ways, replaced X belt, aligned red pointer, aligned mirrors 1 and 2
+
| Extensive interior cleaning, soaked and cleaned optics and carriage, soaked and cleaned autofocus plunger, soaked and cleaned vector table in industrial purple, cleaned optical encoder strip, dusted under cover and re-shimmed the aluminum air assist rod so it doesn't rub on the case or circuit board above the cutting head and leave aluminum powder on the encoder strip and ways, replaced X belt, aligned red pointer, aligned mirrors 1 and 2, corrected manual focus gauge
 
| Rulers need to be readjusted, need new interlock magnets, want new air assist hose
 
| Rulers need to be readjusted, need new interlock magnets, want new air assist hose
 
| [[User:Jason]]
 
| [[User:Jason]]
 
|}
 
|}