Equalogic SAN

From Pumping Station One
Revision as of 05:00, 2 July 2015 by Wikibot (talk | contribs) (Bot: Cosmetic changes)
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Managing

The san has several ip addresses:

10.100.200.2, 10.100.200.10, 10.100.200.11, and 10.100.200.12


There is a java management interface on each one at https://10.100.200.2. This interface rarely works correctly, requires disabling a bunch of java security settings, and the applet is signed with an expired certificate.

The easier, more reliable way

   wget --no-check-certificate https://10.100.200.2/lib/equallogic.jar
   wget --no-check-certificate https://10.100.200.2/lib/eqlresources.jar
   wget --no-check-certificate https://10.100.200.2/lib/plastic_laf.jar
   java -cp "*" com.equallogic.eqlgroupmgr.EqlGroupMgrApplet target=10.100.200.2 debug=true

Mounting San Volumes as iSCSI drives

Arch Linux

   sudo pacman -S open-iscsi

Getting a list of volumes

   sudo iscsiadm -m discovery -t sendtargets -p 10.100.200.10

will print

   10.100.200.2:3260,1 iqn.2001-05.com.equallogic:0-8a0906-c56513102-572fc5aa580519d6-camera-storage
   10.100.200.2:3260,1 iqn.2001-05.com.equallogic:0-8a0906-304513102-98afc44feea537f9-hef-test

Initiating

In iSCSI terms, the initiater is the "client" and the target is the "server".

   iscsiadm -m node --targetname=<targetname> --login
   ls -lh /dev/disk/by-path/*

Now you can make or mount partitions, lvm pvs, or filesystems.


Sarting on boot

After mounting, I get entries in /etc/iscsi/nodes/iqn.2001-05.com.equallogic:0-8a0906-9b6513102-31bfc4554935466d-fizzle-storage/10.100.200.2,3260,1/default

   node.startup = automatic
   node.conn[0].startup = automatic


This still doesn't work, I always need to run sudo iscsiadm -m node -l after booting to get all the volumes to mount


Troubleshooting

We have been getting disconnects from the san. I'm attemping to icnrease the timeout on vm02. I used the following commands

iscsiadm -m node -o update -n node.conn[0].timeo.noop_out_timeout -v 60 iscsiadm -m node -o update -n node.conn[0].timeo.noop_out_interval -v 30