| These are some very vague and poorly collated notes about that: | | These are some very vague and poorly collated notes about that: |
| | | |
− | heat pump stat - but we aren't using the heat pump for heating, so we
| + | heat pump stat - but we aren't using the heat pump for heating, so we |
− | don't even need the fancy board since it's for defrost. we use it when
| + | don't even need the fancy board since it's for defrost. we use it when |
− | we're cooling only. Right now, the wire from the roof is wired to make
| + | we're cooling only. Right now, the wire from the roof is wired to make |
− | it so when power is on (7,9,11) PP1-1 - it runs all the time. There is
| + | it so when power is on (7,9,11) PP1-1 - it runs all the time. There is |
− | no relay control of it that's active. the red wire in the control wire
| + | no relay control of it that's active. the red wire in the control wire |
− | will throw a relay on and off to control the heat pump.
| + | will throw a relay on and off to control the heat pump. |
| | | |
| | | |
− | but, we don't need to use the heat mode of the unit and it's not wired
| + | but, we don't need to use the heat mode of the unit and it's not wired |
− | upstairs for it at the moment, so we should set up the filtrete like so -
| + | upstairs for it at the moment, so we should set up the filtrete like so - |
| | | |
− | take off silver jumper
| + | take off silver jumper |
− | use RC and Y. (normal cooling, not heat pump cooling - the transformer
| + | use RC and Y. (normal cooling, not heat pump cooling - the transformer |
− | is ganged right to the relay up top).
| + | is ganged right to the relay up top). |
− | thin red wire on the transformer goes to RC
| + | thin red wire on the transformer goes to RC |
− | thick red wire from the roof goes to Y
| + | thick red wire from the roof goes to Y |
− | blue and white should be stuck together like they are.
| + | blue and white should be stuck together like they are. |
| | | |
| | | |
− | we also need to put the air handler/fan unit on the coil that hangs down
| + | we also need to put the air handler/fan unit on the coil that hangs down |
− | (big tan thing) run always if the heat pump is on, since it will ice up
| + | (big tan thing) run always if the heat pump is on, since it will ice up |
− | otherwise. However, it's also useful when things aren't in cooling mode
| + | otherwise. However, it's also useful when things aren't in cooling mode |
− | for running some air from outside to the shop, so we want a switch that
| + | for running some air from outside to the shop, so we want a switch that |
− | can manually trigger the relay that will be controlling the air handler.
| + | can manually trigger the relay that will be controlling the air handler. |
| | | |
| === Upstairs === | | === Upstairs === |