Line 19: Line 19:  
From the dryer, air routes through a high efficiency filter and another shutoff valve.
 
From the dryer, air routes through a high efficiency filter and another shutoff valve.
   −
from there, air routes to one or two air circuits.  One feeds the north (3519)shop plus the shopbot and one tap on the central wall in the northeast corner of Hot Metals (3517).  the second circuit (1" pipe) feeds the south shop (Woodhop and Hot Metals 3517) plus the loading dock / spray booth.  [[Media:Airlines.jpg]]
+
From there, air routes to one or two air circuits.  One circuit (3/4 " pipe) feeds the north (3519)shop plus the shopbot and one tap on the central wall in the northeast corner of Hot Metals (3517).  the second circuit (1" pipe) feeds the south shop (Woodhop and Hot Metals 3517) plus the loading dock / spray booth.  [[Media:Airlines.jpg]]
 +
 
 +
There are shutoff valves on the wall between the compressor and dryer for each circuit, labeled as such.
 +
 
 +
There is also a dryer bypass circuit for servicing the dryer while the shop continues to used be fed air.  To effect the bypass,open the valve between the compressor (in vertical piping)and the left side of the house circuit mixing piping and close the valve between the dryer and the right side of the house circuit mixing piping.
    
== Operation ==
 
== Operation ==
1,580