*** After enabling cloud libraries in Fusion 360, you will be able to access your cloud post processor library by setting the Configuration Folder (Windows) or Source (Mac) to My Cloud Posts. Both of these dialog boxes are shown below. You will then be able to select the Cloud post you uploaded in the Post Configuration field (Windows) or the Post Processor field (Mac).
 
*** After enabling cloud libraries in Fusion 360, you will be able to access your cloud post processor library by setting the Configuration Folder (Windows) or Source (Mac) to My Cloud Posts. Both of these dialog boxes are shown below. You will then be able to select the Cloud post you uploaded in the Post Configuration field (Windows) or the Post Processor field (Mac).
 
====Chip Load Calculation====
 
====Chip Load Calculation====
 +
*[https://www.guhdo.com/chipload-calculator Chip Load Calculator by Guhdo]
 
*[http://www.pdsspindles.com/engineering-speeds Bit Parameter Overview by PDS Spindles]
 
*[http://www.pdsspindles.com/engineering-speeds Bit Parameter Overview by PDS Spindles]
 
*[https://www.monstertool.com/29/tech-data.htm Monster Tools Chip Load Calculator]
 
*[https://www.monstertool.com/29/tech-data.htm Monster Tools Chip Load Calculator]
Line 1,194: Line 1,195:  
|David Earl
 
|David Earl
 
|09/29/2019
 
|09/29/2019
 +
|-
 +
|Antina Lee
 +
|David Earl
 +
|09/29/2019
 +
|-
 +
|Rob German
 +
|David Earl
 +
|09/29/2019
 +
|-
 +
|Ryan Zoghlin
 +
|David Earl
 +
|01/25/2020
 
|-}
 
|-}
   Line 1,233: Line 1,246:  
=== Lack of True E-Stop ===
 
=== Lack of True E-Stop ===
 
As shipped, the ShopBot PRS does not support an Emergency Stop. This could be hacked, but it runs the risk of damaging the machine if engaged in a non-emergency situation. Suggested solution: Installing a 10A double pole 24V coil DIN mount relay, and powering the coil via the 24V supply through a normally closed E-Stop button. One pole will disconnect the 63V stepper motor current. One pole will break the control signal that enables the VFD and will cause the VFD to brake to a stop.
 
As shipped, the ShopBot PRS does not support an Emergency Stop. This could be hacked, but it runs the risk of damaging the machine if engaged in a non-emergency situation. Suggested solution: Installing a 10A double pole 24V coil DIN mount relay, and powering the coil via the 24V supply through a normally closed E-Stop button. One pole will disconnect the 63V stepper motor current. One pole will break the control signal that enables the VFD and will cause the VFD to brake to a stop.
  −
=== Automatic Dust Collection ===
  −
The ShopBot has +5V TTL outputs that could be used to trigger automatic dust collection (when the spindle goes live) and/or a warning light (when the gantry is enabled to move.)
      
=== Limit Switch Issues ===
 
=== Limit Switch Issues ===
Cookies help us deliver our services. By using our services, you agree to our use of cookies.

Navigation menu