Changes

Jump to navigation Jump to search
m
Robot: Cosmetic changes
Line 63: Line 63:  
[http://www.shopbottools.com/ShopBotDocs/files/quick%20start%20guide%202013%2007%2023.pdf QuickStart]
 
[http://www.shopbottools.com/ShopBotDocs/files/quick%20start%20guide%202013%2007%2023.pdf QuickStart]
   −
==User Tips & Troubleshooting Reports==
+
== User Tips & Troubleshooting Reports ==
 
Add your experiences with feeds and speeds or other tips here.
 
Add your experiences with feeds and speeds or other tips here.
 
https://wiki.pumpingstationone.org/Shopbot_User_Tips
 
https://wiki.pumpingstationone.org/Shopbot_User_Tips
Line 335: Line 335:  
If you have been authorized but cannot log in, request to be added to the "ShopBot Authorized" Samba group (send an email to info (at) pumpingstationone.org with your username and the name of the person who certified you) so that your login works. If you don't have a log-in on https://members.pumpingstationone.org/ you will have issues here - sign up on that site first if you haven't already.
 
If you have been authorized but cannot log in, request to be added to the "ShopBot Authorized" Samba group (send an email to info (at) pumpingstationone.org with your username and the name of the person who certified you) so that your login works. If you don't have a log-in on https://members.pumpingstationone.org/ you will have issues here - sign up on that site first if you haven't already.
   −
=Maintenance=
+
= Maintenance =
   −
==Maintenance Log==
+
== Maintenance Log ==
 
{| class="wikitable" border="1"
 
{| class="wikitable" border="1"
 
!Date
 
!Date
Line 356: Line 356:  
|}
 
|}
   −
==Outstanding Maintenance Issues==
+
== Outstanding Maintenance Issues ==
   −
===Lack of True E-Stop===
+
=== Lack of True E-Stop ===
 
As shipped, the ShopBot PRS does not support an Emergency Stop. This could be hacked, but it runs the risk of damaging the machine if engaged in a non-emergency situation. Suggested solution: Installing a 10A double pole 24V coil DIN mount relay, and powering the coil via the 24V supply through a normally closed E-Stop button. One pole will disconnect the 63V stepper motor current. One pole will break the control signal that enables the VFD and will cause the VFD to brake to a stop.
 
As shipped, the ShopBot PRS does not support an Emergency Stop. This could be hacked, but it runs the risk of damaging the machine if engaged in a non-emergency situation. Suggested solution: Installing a 10A double pole 24V coil DIN mount relay, and powering the coil via the 24V supply through a normally closed E-Stop button. One pole will disconnect the 63V stepper motor current. One pole will break the control signal that enables the VFD and will cause the VFD to brake to a stop.
   −
===Automatic Dust Collection===
+
=== Automatic Dust Collection ===
 
The ShopBot has +5V TTL outputs that could be used to trigger automatic dust collection (when the spindle goes live) and/or a warning light (when the gantry is enabled to move.)
 
The ShopBot has +5V TTL outputs that could be used to trigger automatic dust collection (when the spindle goes live) and/or a warning light (when the gantry is enabled to move.)
   −
===Limit Switch Issues===
+
=== Limit Switch Issues ===
 
Every time you start the ShopBot, it resets itself so that the limit switches are disabled! You can turn them on (if memory serves) with the Values -> Input Switch Assignment menu item. Limit switches are really useful - but they need to be enabled. When they are, they will stop manual jogging when the limit is hit (although pressing the key again will let you continue moving the gantry) and they will also stop a running job (but give you the option of ignoring the limits.)
 
Every time you start the ShopBot, it resets itself so that the limit switches are disabled! You can turn them on (if memory serves) with the Values -> Input Switch Assignment menu item. Limit switches are really useful - but they need to be enabled. When they are, they will stop manual jogging when the limit is hit (although pressing the key again will let you continue moving the gantry) and they will also stop a running job (but give you the option of ignoring the limits.)
  
WikiBots
1,397

edits

Cookies help us deliver our services. By using our services, you agree to our use of cookies.

Navigation menu