Anonymous

Changes

From Pumping Station One
no edit summary
Line 1: Line 1: −
== The trust relationship between this workstation and the primary domain failed. ==
+
== The Issue ==
   −
I am now documenting this error and things I am trying to do to fix it.
+
Some of the computers on the lan display this error.
    +
<pre>The trust relationship between this workstation and the primary domain failed.</pre>
 +
 +
== Potential Solutions ==
 +
 +
== Reboot ==
 +
 +
Sometimes rebooting clears the error as a workaround
    
== Setting time sync ==
 
== Setting time sync ==
Line 11: Line 18:  
     net start w32time
 
     net start w32time
 
     w32tm /resync
 
     w32tm /resync
 +
 +
Also check the timezone is correct.
 +
 +
Fixes a Potential problem where kerberos and the AD server get out of sync.  Has failed to permanently resolve the problem on sliceyToo, but did make it go away for a day while rebooting failed. 
    
== Reset machine password ==
 
== Reset machine password ==
    
     netdom RESETPWD /Server:bob /UserD:PS1\hef /PasswordD:*
 
     netdom RESETPWD /Server:bob /UserD:PS1\hef /PasswordD:*
 +
 +
 +
Attempted on sliceyToo, has not yet been attempted elsewhere.
Cookies help us deliver our services. By using our services, you agree to our use of cookies.