Filled out tables.
Line 18: Line 18:  
! Exceptions or Limitations
 
! Exceptions or Limitations
 
|-
 
|-
|Some bad material
+
|Ammonia, anhydrous
|Lorem ipsum dolor sit amet
+
|-
 +
|Ammunition, any kind
 +
|Up to 10 small arms cartridges (live or blank) permitted for day use. Live ammunition may not be discharged in the space at any time.
 +
|-
 +
|Asbestos and articles containing asbestos
 +
|Stable non-friable end materials (e.g., floor tiles, brake pads) permitted, but shall not be broken or cut on the property.
 +
|-
 +
|Blasting caps
 +
|
 +
|-
 +
|Controlled substances, Schedule I
 +
|Also see [[Alcohol and Substance Use Policy]].
 +
|-
 +
|Explosive or pyrotechnic articles of any kind
 +
|Consumer fireworks not otherwise restricted by Illinois or Chicago laws are permitted. No use inside the building.
 +
|-
 +
|Gasoline
 +
|Quantities under 1 L are permitted for day use as a motor or appliance fuel only. Storage not allowed.
 +
|-
 +
|Mercury metal
 +
|Sealed mercury thermometers, barometers, etc. are permitted.
 +
|-
 +
|Model rocket motors, class "H" or greater
 +
|
 +
|-
 +
|Nitrocellulose
 +
|
 +
|-
 +
|Nitroglycerin
 +
|Pharmaceutical preparations are permitted.
 +
|-
 +
|Nitrous oxide
 +
|
 +
|-
 +
|Organic peroxides
 +
|
 +
|-
 +
|Radioactive material
 +
|Safety-sealed disk sources of 10 µCi or less, and needle sources of 0.01 µCi or less, are permitted without restriction.
 +
|-
 +
|Smoke grenades or smoke bombs
 +
|Consumer fireworks not otherwise restricted by Illinois or Chicago laws are permitted. No use inside the building.
 +
|-
 +
|Tear gas and tear gas candles
 +
|
 
|}
 
|}
   Line 45: Line 89:  
!Storage restrictions
 
!Storage restrictions
 
|-
 
|-
|Water
+
|Acetylene gas
|Don't get up your nose
+
|Used with torches (welding, jeweler's, etc.) only in Small Metals and Hot Metals
|30 L
+
|Three "B" cylinders in each of Small Metals and Hot Metals for shared use.
|Need watertight container
+
|Personal storage prohibited. Area supply to be chained up and capped when not in use.
 +
|-
 +
|Charcoal lumps or briquettes
 +
|Burning inside building not allowed
 +
|25 kg
 +
|-
 +
|Cotton
 +
|None. Oily rags to be disposed of in proper place.
 +
|No limit.
 +
|No restriction.
 +
|-
 +
|Denatured alcohol
 +
|Ventilation required during use.
 +
|5 L total
 +
|Store in flammables cabinet only.
 +
|-
 +
|Ethanol (ethyl alcohol)
 +
|Ventilation required during use. Also see [[Alcohol and Substance Use Policy]].
 +
|5 L
 +
|Store concentrations above 60% (by vol.) in flammables cabinet only. Beverage-grade alcohol shall be kept in locked storage only.
 +
|-
 +
|Extracts, aromatic or flavoring, liquid
 +
|None.
 +
|No limit.
 +
|Prevent or control any leak that may create a nuisance.
 +
|-
 +
|Kerosene
 +
|For use as a cleaner or solvent only. Kerosene heaters are prohibited inside the building.
 +
|5 L total
 +
|Store in flammables cabinet only.
 +
|-
 +
|Magnesium (or alloys), powder
 +
|None.
 +
|100 g
 +
|None.
 +
|-
 +
|Methanol (methyl alcohol)
 +
|Use in paint booth only.
 +
|1 L total
 +
|Store in flammables cabinet only.
 +
|-
 +
|Methyl ethyl ketone (ethyl methyl ketone, MEK)
 +
|Use in paint booth only.
 +
|5 L total
 +
|Store in flammables cabinet only.
 +
|-
 +
|Model rocket motors, class "C" or below
 +
|Not to be used inside the building.
 +
|Five motors.
 +
|No restriction.
 +
|-
 +
|Oxygen, compressed, industrial
 +
|Used as part of a welding set only.
 +
|Three "B" cylinders in each of Small Metals and Hot Metals for shared use.
 +
|Personal storage prohibited. Cylinders to be chained up and capped when not in use. Storage in flammables cabinet is strictly prohibited.
 +
|-
 +
|Oxygen, compressed, medical
 +
|To be used on prescription only.
 +
|Not allowed.
 +
|Personal storage prohibited.
 +
|-
 +
|Paint, lacquer or solvent base, aerosol
 +
|Use in paint booth only.
 +
|10 L total
 +
|Store in flammables cabinet only.
 +
|-
 +
|Paint, oil-based
 +
|Spray application, and brush applications 30 cm² or greater, in paint booth only
 +
|10 L total
 +
|Store in flammables cabinet only.
 +
|-
 +
|Paint, water-based
 +
|No limitations.
 +
|No limit.
 +
|No restrictions. Store in a way that prevents leakage (double-bagging, etc.)
 +
|-
 +
|Petroleum distillates (paint thinner, Stoddard solvent, WD-40®, and similar)
 +
|Spray applications or applications over 30 cm² with good ventilation only (with roof ventilators on in General/Cold Metals Areas, or in paint booth)
 +
|5 L total
 +
|Store in flammables cabinet only.
 +
|-
 +
|Petroleum gases, compressed/liquified (includes propane, butane, etc.)
 +
|For use as a fuel only, with proper ventilation.
 +
|One "B" cylinder in each of Small Metals and Hot Metals for shared use. Five "blowtorch" cylinders (or smaller) total in flammables cabinet.
 +
|Small cylinders must be stored in flammables cabinet only. Large cylinders to be chained up and capped when not in use.
 +
|-
 +
|Petroleum oil, heavy (motor oil, etc.)
 +
|Clean up any spills promptly to prevent slips.
 +
|No limit.
 +
|No restrictions.
 +
|-
 +
|Self-defense spray (pepper spray, etc.)
 +
|Emergency use only.
 +
|No limit.
 +
|No restrictions.
 +
|-
 +
|Sodium hydroxide, solid or liquid
 +
|Use on a liquid-proof surface only. If left unattended, must be prominently signed, "Warning - Corrosive."
 +
|No limit.
 +
|Liquid preparations must be stored in a leak-proof manner (double-bagging, etc.).
 +
|-
 +
|Solvents, flash point below 38°C (such as toluene, xylene, benzene, turpentine)
 +
|Use in paint booth only.
 +
|5 L total.
 +
|Store in flammables cabinet only.
 +
|-
 +
|Tetrachloroethylene (brake cleaner)
 +
|Use with good ventilation only (with roof ventilators on in General/Cold Metals Areas, or in paint booth)
 +
|1 L
 +
|No restriction
 
|}
 
|}
  