Line 1: |
Line 1: |
| == Collector Mounting == | | == Collector Mounting == |
| | | |
− | Install the collector in the pallet rack behind the Shopbot. This will make the mounting of the motor easy and provide a framework for a sound enclosure, if necessary. The collector motor will be mounted on top of a piece of 3/4 plywood that is secured to the top shelf of the rack. | + | Install the collector in the pallet rack behind the Shopbot. This will make the mounting of the motor easy and provide a framework for a sound enclosure, if necessary. The collector motor will be mounted on top of a piece of 3/4 plywood that is secured to the top shelf of the rack. |
| | | |
− | The approximate dimensions of the rack are 44" wide x 33" deep x 8.5' tall. Dimensions of the collector without the inlet tube are approximately 24"x34"x8'. (is this also true for the nano filter?) | + | The approximate dimensions of the rack are 44" wide x 33" deep x 8.5' tall. Dimensions of the collector without the inlet tube are approximately 24"x34"x8'. (is this also true for the nano filter?) |
| | | |
| Inlet port on dust collector is angled up at 11 degrees. | | Inlet port on dust collector is angled up at 11 degrees. |
Line 11: |
Line 11: |
| == Ducting == | | == Ducting == |
| | | |
− | An 8" main duct will begin at the collector and run parallel to the trusses and below towards the shopbot and across the shop towards the woodworking area. | + | An 8" main duct will begin at the collector and run parallel to the trusses and below towards the shopbot and across the shop towards the woodworking area. |
| | | |
| To reduce turbulence in the collector, first 5 feet should be straight with no fittings. | | To reduce turbulence in the collector, first 5 feet should be straight with no fittings. |
Line 27: |
Line 27: |
| Clearvue blast gates are sized for PVC pipe. | | Clearvue blast gates are sized for PVC pipe. |
| | | |
− | Clearvue: If PVC is used, the pipe can be grounded with a wire run on the outside of the pipe, attached to a screw driven into the pipe every 5 feet. The screw running into the interior of the pipe will drain off any charge. | + | Clearvue: If PVC is used, the pipe can be grounded with a wire run on the outside of the pipe, attached to a screw driven into the pipe every 5 feet. The screw running into the interior of the pipe will drain off any charge. |
| | | |
| PVC pipe quotes (sch. 40 is heavier than we need, the pipe is co stenciled sch 40/DWV) | | PVC pipe quotes (sch. 40 is heavier than we need, the pipe is co stenciled sch 40/DWV) |
Line 33: |
Line 33: |
| Columbia 8" sch 40 $7.40/ft, 6" 4.85/ft | | Columbia 8" sch 40 $7.40/ft, 6" 4.85/ft |
| | | |
− | software to create templates to join pvc pipe. | + | software to create templates to join pvc pipe. |
| http://www.harderwoods.com/pipedocs.html | | http://www.harderwoods.com/pipedocs.html |
| | | |