Anonymous

Changes

From Pumping Station One
m
Robot: Cosmetic changes
Line 1: Line 1:  
== Collector Mounting ==
 
== Collector Mounting ==
   −
Install the collector in the pallet rack behind the Shopbot. This will make the mounting of the motor easy and provide a framework for a sound enclosure, if necessary. The collector motor will be mounted on top of a piece of 3/4 plywood that is secured to the top shelf of the rack.
+
Install the collector in the pallet rack behind the Shopbot. This will make the mounting of the motor easy and provide a framework for a sound enclosure, if necessary. The collector motor will be mounted on top of a piece of 3/4 plywood that is secured to the top shelf of the rack.  
   −
The approximate dimensions of the rack are 44" wide x 33" deep x 8.5' tall. Dimensions of the collector without the inlet tube are approximately 24"x34"x8'. (is this also true for the nano filter?)
+
The approximate dimensions of the rack are 44" wide x 33" deep x 8.5' tall. Dimensions of the collector without the inlet tube are approximately 24"x34"x8'. (is this also true for the nano filter?)
    
Inlet port on dust collector is angled up at 11 degrees.
 
Inlet port on dust collector is angled up at 11 degrees.
Line 11: Line 11:  
== Ducting ==
 
== Ducting ==
   −
An 8" main duct will begin at the collector and run parallel to the trusses and below towards the shopbot and across the shop towards the woodworking area.
+
An 8" main duct will begin at the collector and run parallel to the trusses and below towards the shopbot and across the shop towards the woodworking area.  
 
   
 
   
 
To reduce turbulence in the collector, first 5 feet should be straight with no fittings.
 
To reduce turbulence in the collector, first 5 feet should be straight with no fittings.
Line 27: Line 27:  
Clearvue blast gates are sized for PVC pipe.
 
Clearvue blast gates are sized for PVC pipe.
   −
Clearvue: If PVC is used, the pipe can be grounded with a wire run on the outside of the pipe, attached to a screw driven into the pipe every 5 feet. The screw running into the interior of the pipe will drain off any charge.
+
Clearvue: If PVC is used, the pipe can be grounded with a wire run on the outside of the pipe, attached to a screw driven into the pipe every 5 feet. The screw running into the interior of the pipe will drain off any charge.
    
PVC pipe quotes (sch. 40 is heavier than we need, the pipe is co stenciled sch 40/DWV)
 
PVC pipe quotes (sch. 40 is heavier than we need, the pipe is co stenciled sch 40/DWV)
Line 33: Line 33:  
Columbia 8" sch 40 $7.40/ft, 6" 4.85/ft
 
Columbia 8" sch 40 $7.40/ft, 6" 4.85/ft
   −
software to create templates to join pvc pipe.
+
software to create templates to join pvc pipe.  
 
http://www.harderwoods.com/pipedocs.html
 
http://www.harderwoods.com/pipedocs.html
  
WikiBots
1,397

edits

Cookies help us deliver our services. By using our services, you agree to our use of cookies.