The RFID reader is TYPE and is plugged directly into the control board.
The RFID reader is TYPE and is plugged directly into the control board.
−
Wiring colors
+
This is the wiring scheme that comes directly out of the reader. The wires that come out of the wall are listed below.
+
*Red - +12v DC
*Red - +12v DC
*Black - GND
*Black - GND
Line 41:
Line 42:
*Orange - Doorbell switch
*Orange - Doorbell switch
*Brown - Doorbell switch
*Brown - Doorbell switch
+
+
+
=Wiring=
+
There are 2 wiring buses in parallel to make the doorbell/doorstrike/data transfer work. They connect to 2 terminal blocks at each doorway. Everything currently runs on 12v.
+
+
===Brown 8 conductor wire===
+
This wire supports the doorbell button, strike actuation, and ring.
+
*Red - +12v DC
+
*Black - GND
+
*White -
+
*Green -
+
*Blue -
+
*Yellow -
+
*Orange - Back door strike
+
*Brown - Front door strike
+
+
===Grey CAT3 6-pair wire===
+
This wire supports the RFID reader wires directly. Note that the twisted pairs are different than normal.
+
+
The Cat 3 was used to extend the short RFID wire and below is how the wires map. Note: the Grey and Yellow wires from the RFID reader are not connected to the Cat 3 and terminate in the tube that passes the cable through the wall.
+
+
*Red and Blue striped pair - Red - +12v DC
+
*White/Grey and Grey pair - Black - GND
+
*White/Green and White/Blue pair - White - D1 / TX