Difference between revisions of "The trust relationship between this workstation and the primary domain failed"
Jump to navigation
Jump to search
(No difference)
|
Revision as of 00:15, 19 July 2014
The Issue
Some of the computers on the lan display this error.
The trust relationship between this workstation and the primary domain failed.
Potential Solutions
Reboot
Sometimes rebooting clears the error as a workaround
Setting time sync
w32tm /config /manualpeerlist:bob.ad.pumpingstationone.org,0x8 /syncfromflags:MANUAL w32tm /config /update net stop w32time net start w32time w32tm /resync
Also check the timezone is correct.
Fixes a Potential problem where kerberos and the AD server get out of sync. Has failed to permanently resolve the problem on sliceyToo, but did make it go away for a day while rebooting failed.
Reset machine password
netdom RESETPWD /Server:bob /UserD:PS1\hef /PasswordD:*
Attempted on sliceyToo, has not yet been attempted elsewhere.