== Getting an Access Code == | == Getting an Access Code == | ||
− | In order to get the access code, you should A: be a paying member in good standing with the organization, and B: have your [[Bylaws#Eligibility | id checked]] by 2 board members. | + | In order to get the access code, you should A: be a paying member in good standing with the organization, and B: have your [[Bylaws#Eligibility|id checked]] by 2 board members. The best time to get your ID checked is at a general meeting which occur every Tuesday at 8:00pm. |
== Reprogramming the Lock == | == Reprogramming the Lock == | ||
The full manual is available at http://www.alarmlock.com/images/pdf/ETPDL_PDL3X00_WI1021C.07_PROG.pdf | The full manual is available at http://www.alarmlock.com/images/pdf/ETPDL_PDL3X00_WI1021C.07_PROG.pdf | ||
+ | |||
+ | * The document may not render the keypad font correctly, making the document useless. | ||
+ | ** It fails to render correctly in firefox, and OS X's preview application. | ||
+ | ** It renders correctly in [https://get.adobe.com/reader/ Adobe Reader] for OS X. | ||
+ | ** It renders correctly in Chrome. | ||
+ | |||
+ | == Sharing the door code == | ||
+ | |||
+ | * Please don't share the door code with non-members | ||
+ | * If you don't have the ability to verify membership status, please don't give out the door code. | ||
+ | |||
+ | == Changing the door code == | ||
+ | |||
+ | Door code logic: each allowed code is associated with a user id between the numbers 12 and 50, inclusive. | ||
+ | |||
+ | The door codes are documented on a ''User Code Record Sheet'' that is stored in the safe. | ||
+ | |||
+ | === Programming the door === | ||
+ | |||
+ | To program the door, enter programming mode and enter function codes. All function codes take the form <code>A {function code} (A params) *</code>. While programming mode is enabled, the door will beep every few seconds. You may enter functions until you exit programming mode. To Exit Programming mode, hold down any button for 3 seconds. | ||
+ | |||
+ | |||
+ | <code>{MASTER CODE} A</code> | ||
+ | |||
+ | You are now in program mode until you hold a button for 3 seconds. | ||
+ | |||
+ | ==== Adding ==== | ||
+ | |||
+ | <code>A 2 A {User ID} A {CODE} *</code> | ||
+ | |||
+ | ==== Deleting ==== | ||
+ | |||
+ | <code>A 2 A {USER ID} *</code> | ||
+ | |||
+ | ==== Temporarily Unlocking ==== | ||
+ | |||
+ | <code>A 47 A {HOURS} *</code> | ||
+ | |||
+ | == Erasing All Programing == | ||
+ | |||
+ | # Remove battery | ||
+ | # Hold down A for 10 seconds (drain the capaciters) | ||
+ | # Reinstall Battery | ||
+ | # withing 5 seconds of hearing 3 beeps, Hold A until it beeps more | ||
+ | # The lock is now reset, the master programming code is now the default. |
Latest revision as of 21:40, 7 September 2014
Owner/Loaner | PS:One |
---|---|
Serial Number | {{{serial}}} |
Make/Model | PDL3000 |
Arrival Date | {{{arrived}}} |
Usability | yes |
Contact | {{{contact}}} |
Where | Installed on Front Door |
Authorization Needed | yes |
Hackable | yes |
Estimated Value | ~$1000 |
Host Area | {{{hostarea}}} |
Getting an Access Code
In order to get the access code, you should A: be a paying member in good standing with the organization, and B: have your id checked by 2 board members. The best time to get your ID checked is at a general meeting which occur every Tuesday at 8:00pm.
Reprogramming the Lock
The full manual is available at http://www.alarmlock.com/images/pdf/ETPDL_PDL3X00_WI1021C.07_PROG.pdf
- The document may not render the keypad font correctly, making the document useless.
- It fails to render correctly in firefox, and OS X's preview application.
- It renders correctly in Adobe Reader for OS X.
- It renders correctly in Chrome.
Sharing the door code
- Please don't share the door code with non-members
- If you don't have the ability to verify membership status, please don't give out the door code.
Changing the door code
Door code logic: each allowed code is associated with a user id between the numbers 12 and 50, inclusive.
The door codes are documented on a User Code Record Sheet that is stored in the safe.
Programming the door
To program the door, enter programming mode and enter function codes. All function codes take the form A {function code} (A params) *
. While programming mode is enabled, the door will beep every few seconds. You may enter functions until you exit programming mode. To Exit Programming mode, hold down any button for 3 seconds.
{MASTER CODE} A
You are now in program mode until you hold a button for 3 seconds.
Adding
A 2 A {User ID} A {CODE} *
Deleting
A 2 A {USER ID} *
Temporarily Unlocking
A 47 A {HOURS} *
Erasing All Programing
- Remove battery
- Hold down A for 10 seconds (drain the capaciters)
- Reinstall Battery
- withing 5 seconds of hearing 3 beeps, Hold A until it beeps more
- The lock is now reset, the master programming code is now the default.