Line 4: |
Line 4: |
| |model=Mitsui 250MH | | |model=Mitsui 250MH |
| |arrived=Late 2016 | | |arrived=Late 2016 |
− | |doesitwork=yes | + | |doesitwork=no |
| |contact=Dean Anderson | | |contact=Dean Anderson |
− | |where=Cold Metals | + | |where=Removed |
| |certification=yes | | |certification=yes |
| |hackable=no | | |hackable=no |
| |value=~$3000 | | |value=~$3000 |
− | |hostarea=Cold Metals | + | |hostarea= |
| }} | | }} |
| + | |
| + | Removed by owner |
| + | |
| | | |
| == Repair and Setup== | | == Repair and Setup== |
Line 23: |
Line 26: |
| ## Replace way wipers. | | ## Replace way wipers. |
| ## Fix y-axis oil lines. | | ## Fix y-axis oil lines. |
| + | ## Reinspect/regrind table and chuck. |
| # Clean Z ways. | | # Clean Z ways. |
| # Replace Z way pleated covers. | | # Replace Z way pleated covers. |
| # Install VFD. | | # Install VFD. |
− | # Mount/grind in a chuck.
| |
| # Develop an authorization plan. | | # Develop an authorization plan. |
| # Set up dust collection. | | # Set up dust collection. |
| | | |
| == Maintenance == | | == Maintenance == |
− | === Diagnosis === | + | === Current Status === |
| + | The small electromagnetic sine chuck was mounted and ground in to less than a tenth on 2017-03-12. |
| + | |
| + | === Further Diagnosis === |
| After initial repair, diagnosis of further issues will come via a test grind. | | After initial repair, diagnosis of further issues will come via a test grind. |
| | | |
Line 38: |
Line 44: |
| # Five block test can be used as a rough diagnosis. | | # Five block test can be used as a rough diagnosis. |
| | | |
− | === Table Removal === | + | === Procedures === |
| + | ==== Table Removal ==== |
| The table needs to be removed periodically to clean the grinding grit from the ways. | | The table needs to be removed periodically to clean the grinding grit from the ways. |
| | | |
Line 45: |
Line 52: |
| # Remove the nut at the end of the cable on the right side under the table. Fasten a weight to the end of the cable to prevent the cable from unwinding on the capstan. | | # Remove the nut at the end of the cable on the right side under the table. Fasten a weight to the end of the cable to prevent the cable from unwinding on the capstan. |
| | | |
− | === Moving the grinder === | + | ==== Moving the grinder ==== |
| ''Never move the grinder without coordinating with Dean, the owner.'' | | ''Never move the grinder without coordinating with Dean, the owner.'' |
| | | |
| The two table ball cages need to be removed anytime the grinder is moved. This is necessary to prevent the races from Brinelling. To remove the ball cages, disconnect the X axis cable at each end of the table then prop up the ends of the table. | | The two table ball cages need to be removed anytime the grinder is moved. This is necessary to prevent the races from Brinelling. To remove the ball cages, disconnect the X axis cable at each end of the table then prop up the ends of the table. |
| + | |
| + | [[Category:Loaned Equipment]] |