Sept 24 2021. Report that the blade stopped motor stopped and smoke was billowing from motor box and ductwork. After a long rest, it was tested and no fault found.  Stress tested 9/26 and put back into service.  Gn
 
Sept 24 2021. Report that the blade stopped motor stopped and smoke was billowing from motor box and ductwork. After a long rest, it was tested and no fault found.  Stress tested 9/26 and put back into service.  Gn
 +
 +
March -may 2022. Long series of machine errors ranging from false brake firings to blade rot error code to no power at controller. Lots of troubleshooting and blade brake replacements.  Also replaces start cap.per sawstop direction.  Worked short while then happened again. On may 19, EB replaced run capacitor.  Hoping that this works.
    
this very heavy duty version of the SawStop was installed January 2020
 