Line 7: |
Line 7: |
| |serial = SERIAL NUMBER | | |serial = SERIAL NUMBER |
| |arrived = May 2018 | | |arrived = May 2018 |
− | |where = Hot Metals | + | |where = Removed |
| |doesitwork = "yes" | | |doesitwork = "yes" |
| |contact = Hot Metals area host | | |contact = Hot Metals area host |
Line 16: |
Line 16: |
| == Status == | | == Status == |
| | | |
− | A certification process is still being worked out. If you want to help with that check in with the small metals area host. | + | A certification process is still being worked out, very close to completed. If you want to help with that check in with the hotmetals area host. |
| | | |
| | | |
| == Safety == | | == Safety == |
| | | |
| + | *Eye protection required |
| + | *Flammable Gas |
| + | *Burns |
| + | *It's loud |
| + | *you might want a respirator |
| | | |
− | *Burns
| + | == Use == |
| | | |
− | Area
| + | Prep |
| | | |
| + | *Clean up, vacuum up debris that has fallen out of the exhaust duct. It's plastic-ee and smells horrid and very unhealthy when it burns. |
| + | *Stack pile-O-bricks around the slot to suit your work. The entire slot must be covered. |
| + | *Make sure there is nothing flammable on the top of the forge. |
| | | |
| + | Start up |
| | | |
| + | *Turn on the exhaust fan with the timer switch on the wall. |
| + | *Open the valve on the tank. |
| + | *Open the slot forge valve on the manifold on the wall. |
| + | *Press the start button on the front of the forge. |
| | | |
| + | Shut Down |
| | | |
| + | *Press the stop button on the front of the forge. |
| + | *Close the slot forge valve on the manifold on the wall. |
| + | *Close the valve on the tank. |
| + | *Leave an indicator that the area is hot. |
| | | |
| | | |
| | | |
| '''This tool requires certification for use.''' | | '''This tool requires certification for use.''' |
− | == List of Currently Certified Users ==
| |
− | {| class="wikitable" border="1"
| |
− | ! Qualified Member
| |
− | ! Trained By
| |
− | |-
| |
− | |Name of member
| |
− | |Who qualified them
| |
− | |-
| |
− | |Michael Skilton
| |
− | |Danger committee
| |
− | |
| |
− | |-}
| |