# Remove saddle, clean ways and check turcite for damage. | # Remove saddle, clean ways and check turcite for damage. | ||
− | # Z ways | + | # Remove the grinder from the pallet and align parallel to the long wall. Set up the materials storage and maybe plywood on the right side. |
+ | # Install a full wheel guard. | ||
+ | # Clean Z ways. | ||
# Replace Z way pleated covers. | # Replace Z way pleated covers. | ||
# Fill lubrication tank with correct oil. Check that all oil lines are working. | # Fill lubrication tank with correct oil. Check that all oil lines are working. | ||
− | |||
− | |||
# Develop an authorization plan. | # Develop an authorization plan. | ||
− | == Diagnosis == | + | == Maintenance == |
+ | === Diagnosis === | ||
After initial repair, diagnosis of further issues will come via a test grind. | After initial repair, diagnosis of further issues will come via a test grind. | ||
Line 34: | Line 35: | ||
# Five block test can be used as a rough diagnosis. | # Five block test can be used as a rough diagnosis. | ||
− | == Table Removal == | + | === Table Removal === |
The table needs to be removed periodically to clean the grinding grit from the ways. | The table needs to be removed periodically to clean the grinding grit from the ways. | ||
− | The table is heavy. We need a system for lifting the table off of the saddle. | + | The table is heavy. We need a system for lifting the table off of the saddle. The engine hoist doesn't work well. Perhaps a ceiling supported crane would work. |
# Remove the nut at the end of the cable on the right side under the table. Fasten a weight to the end of the cable to prevent the cable from unwinding on the capstan. | # Remove the nut at the end of the cable on the right side under the table. Fasten a weight to the end of the cable to prevent the cable from unwinding on the capstan. | ||
− | == Moving the grinder == | + | === Moving the grinder === |
+ | ''Never move the grinder without coordinating with Dean, the owner.'' | ||
+ | |||
The ball ways need to be removed anytime the grinder is moved. This is necessary to prevent the races from Brinelling. To remove the ball ways, disconnect the X axis cable at each end of the table then prop up the ends of the table. | The ball ways need to be removed anytime the grinder is moved. This is necessary to prevent the races from Brinelling. To remove the ball ways, disconnect the X axis cable at each end of the table then prop up the ends of the table. |
Revision as of 02:19, 23 February 2017
This tool is currently broken, please contact the area host for more information. |
File:Mitsui250mh.jpg | |
Owner/Loaner | Dean Anderson |
---|---|
Serial Number | {{{serial}}} |
Make/Model | Mitsui 250MH |
Arrival Date | Late 2016 |
Usability | so close |
Contact | Dean Anderson |
Where | Cold Metals |
Authorization Needed | yes |
Hackable | no |
Estimated Value | ~$3000 |
Host Area | Cold Metals |
Repair and Setup
All repair needs to be coordinated with the area host.
Motor bearings were replaced, to great success. Ball ways and table are installed. Test grinds are showing good repeatability. A grit and light parts catcher is installed on the left hand side.
- Remove saddle, clean ways and check turcite for damage.
- Remove the grinder from the pallet and align parallel to the long wall. Set up the materials storage and maybe plywood on the right side.
- Install a full wheel guard.
- Clean Z ways.
- Replace Z way pleated covers.
- Fill lubrication tank with correct oil. Check that all oil lines are working.
- Develop an authorization plan.
Maintenance
Diagnosis
After initial repair, diagnosis of further issues will come via a test grind.
- The table may need to be ground in.
- A mag chuck will need to be ground in and swept with an indicator.
- Five block test can be used as a rough diagnosis.
Table Removal
The table needs to be removed periodically to clean the grinding grit from the ways.
The table is heavy. We need a system for lifting the table off of the saddle. The engine hoist doesn't work well. Perhaps a ceiling supported crane would work.
- Remove the nut at the end of the cable on the right side under the table. Fasten a weight to the end of the cable to prevent the cable from unwinding on the capstan.
Moving the grinder
Never move the grinder without coordinating with Dean, the owner.
The ball ways need to be removed anytime the grinder is moved. This is necessary to prevent the races from Brinelling. To remove the ball ways, disconnect the X axis cable at each end of the table then prop up the ends of the table.